Description
SPECIAL FEATURES
- All Welded Media Chamber
- Static Pressure Up To 600 psi
- Overload Safety Ensured by All Metal Construction
- Standard Followed ASME ?B.40.1 / EN837-3
- IP:66
SPECIFICATION
- Ambient Temperature : -4 ?F (-20?C) to + 150?F (+65?C)
- Process Temperature : Max. 212?F (+100?C)
- Operating Pressure Range : 75% of Scale Value
- Over Pressure Limit : 125% of Max. Scale Value
- Case : AISI 304 SS
- Joints : Tig Argon Arc Welding
- Chamber: AISI 316 SS
- Diaphragm : AISI 316L SS
- Movement : AISI 304 SS
- Dial : Aluminum
- Pointer : Micro Zero Adjustable
- Window : Safety Glass
- Range : Vacuum to 15″WC-160psi
- ACCURACY AS PER ASME B.40.1
- 4?/6? : 2-1-2 (GRADE A)